Hyundai HX200L-2000 Manuel d'utilisateur Page 65

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 147
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 64
3. Instructions
3-7
3.4. How to Install
NOTE:
Before starting to unpack and install the robot, read the safety regulations and other
instructions very carefully..
Warning:
The installation shall be made by qualified installation personnel and should conform
to all national and local codes.
When unpacking the robot, check if it has been damaged during transporting or
unpacking. In addition, strictly keep the following installation instructions because
installation method and foundation are very important to maintain a good robot
performance.
3.4.1. Operating Conditions
(1) Ambient temperature should range from 0 to 45.
(2) Ambient humidity should range from 20% to 85% RH, without dew
condensation.
(3) Less dust, oil, or moisture.
(4) No flammable, corrosive liquid or GAS.
(5) No impact and shacking.
(6) No electrical noise generator near the robot.
(7) If the robot is not immediately installed, keep it in a dry area at an ambient
temperature between -15 and 40 . ℃∼